
·
D.
CONTROLS AND WHAT THEY DO
The controls are divided
into
two
areas.
Those
on
the
Main
Control
Box (W) and those
on
the
Meter
Console X
(see
Diagram
3l.
On/Off Tune Switch
IQI-
See
Tuning P.6.
Function Switch/Ground Exclude lSI
This
control
selects
for
the
type
of
site.
The
MET
ADEC
II can be used
as
a professional
BEACH
or
IN
LAND
detector
even
though
the
ground
conditions are
totally
different.
Select
either:-
INLAND
-
Two
positions,
G·MAX
-
01
and
G·MAX
-
02
or
BEACH -
Two
positions,
G·MAX
-
01
and
G·MAX
-
02
When operating in
the
PROGRAMMED
OPERATION
METHOD
IC)
it
is
only
important
to
set the
FUNCTION
SWITCH
to
either
INLAND
or
BEACH.
If
the
Function
Switch
is
on
BEACH,
and
the
detector
is
operated on
an
inland site
or
vice versa, the level
of
PRE·SET
Ground
will
not
be
correct.
When operated
in
the
ADC
Method
the
Function
Switch
can
be
used
in
two
positions:
G·MAX
-
01
G·MAX
-
02
The
G·MAX
channel
is
the
all metal ground excluding channel and
is
the
same
in
both
positions.
01
is
a discriminating channel and discriminates against most iron and small
foil.
02
is
a second
discriminating
channel and gives higher levels
of
discrimination
including larger
silver
foil
and
pull
tabs
if
required.
Each 0 channel
is
variable
by
adjusting
the
Discrimination
Level (T).
The
principle
of
the
ADC
method
is
to
search in a ground excluding mode
G·MAX,
and then
after
a signal
is
received
switch
to
a
discriminating
mode 01
or
02
to
analyse the target object
(detailed setting
up
in
the
AOC
mode
is
described
in
Section E laterl.
Manual Ground Exclude IZ)
Ground
exclusion,
which
is
the
process
of
eliminating
signals caused
by
mineralisation in
the
ground
can be manually set
by
ensuring
that
the Pre·set push
button
(i)
on
the
meter console
is
OFF,
and
tuning
the
Ground
Exclude
Control
(Zl.
After
tuning
the
detector,
using ground
button
(vi) and ensuring
that
811
the meter console push
buttons
are
off
lcheck status
(vI),
start
with
the
Ground
Exclude
control
(Z) set
at
O.
Lower
the
search head
to
the
ground
from
about
50 cms away.
If
the meter setting decreases
(to
the
left)
as
the head
is
lowered.
turn
the
Ground
Exclude
Control
(Z) anti·c1ockwise gradually and repeat
until
the meter maintains a central
tuned
position
when lowered
to
the ground.
Conversely, when
you
lower
the search head and
the
meter signal increases (goes
up
to
the
right)
turn
the
ground exclusion
control
clockwise gradually
until
the
meter's central position
is
maintained
throughout
lowering the
detector
head
to
the ground.
If
you
engage
the
PRE-SET
Ground
(i).any
setting
of
the manual Ground Exclude
control
will
be over-
ridden,
so
ensure
if
you
require manual
control
because the site
is
unusual,
that
the
PRE·SET
is
not
engaged.
7
Komentáře k této Příručce